Pay in installments of $46.03 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 20 - Jul 25
For Your Every Summer RSVP, with Code: SUMMER15
Description
Human MGL ELISA KitProduct Specification Usage Required experimental equipment: 1. Microplate reader (450nm) 2. High precision pipettes and pipette tips: 0. 5 10uL, 5 50uL, 20 200uL, 200 1000uL 3. 37C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre chilled PBS (0. 01M, pH 7. 4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and
Product Specification
| Usage | Required experimental equipment: 1. Microplate reader (450nm) 2. High-precision pipettes and pipette tips: 0.5-10uL, 5-50uL, 20-200uL, 200-1000uL 3. 37°C incubator 4. Distilled or deionized water Sample preparation and requirements: Tissue homogenization: Rinse the tissue with pre-chilled PBS (0.01M, pH 7.4) to remove residual blood (lysed red blood cells in the homogenate will affect the measurement results). Weigh and mince the tissue. Add the minced tissue to the appropriate volume of PBS (generally a 1:9 weight-to-volume ratio, e.g., 1g of tissue sample to 9mL of PBS. The specific volume can be adjusted according to experimental needs and recorded. It is recommended to add protease inhibitors to the PBS) in a glass homogenizer and grind thoroughly on ice. To further lyse tissue cells, the homogenate can be ultrasonically disrupted or repeatedly frozen and thawed. Finally, the homogenate is centrifuged at 5000×g for 5-10 minutes and the supernatant is collected for analysis. Other biological fluids: Centrifuge at 1000xg for 20 minutes, remove the supernatant, and test. Pre-test preparation: 1. Remove the test kit from the refrigerator 10 minutes in advance and equilibrate to room temperature. 2. Prepare the standard gradient working solution: Add 1 mL of universal diluent to the lyophilized standard, let it stand for 15 minutes to completely dissolve, then gently mix (concentration is 10 ng/mL). Then dilute to the following concentrations: 10 ng/mL, 5 ng/mL, 2.5 ng/mL, 1.25 ng/mL, 0.625 ng/mL, 0.3125 ng/mL, 0.15625 ng/mL, and 0 ng/mL. Serial dilution method: Take seven EP tubes and add 500uL of universal diluent to each. Pipette 500uL of the 10ng/mL standard working solution into the first EP tube and mix thoroughly to make a 5ng/mL standard working solution. Repeat this procedure for subsequent tubes. The last tube serves as a blank well; there is no need to pipette liquid from the penultimate tube. See the figure below for details. 3. Preparation of biotinylated detection antibody working solution: Centrifuge the concentrated biotinylated antibody at 1000×g for 1 minute 15 minutes before use. Dilute the 100× concentrated biotinylated antibody to a 1× working concentration with universal diluent (e.g., 10uL concentrate + 990uL universal diluent). Prepare and use immediately. 4. Prepare the enzyme conjugate working solution: 15 minutes before use, centrifuge the 100× concentrated enzyme conjugate at 1000×g for 1 minute. Dilute the 100× concentrated HRP enzyme conjugate to a 1× working concentration with universal diluent (e.g., 10 μL of concentrate + 990 μL of universal diluent). Prepare immediately. 5. Prepare the 1× wash solution: Dispense 10 mL of 20× wash solution into 190 mL of distilled water (concentrated wash solution removed from the refrigerator may crystallize; this is normal. Allow to stand at room temperature until the crystals have completely dissolved before preparing). Procedure: 1. Remove the desired strips from the aluminum foil bag after equilibration at room temperature for 10 minutes. Seal the remaining strips in a ziplock bag and return to 4°C. 2. Sample addition: Add 100 μL of sample or standard of varying concentrations to the corresponding wells. Add 100 μL of universal diluent to the blank wells. Cover with a film and incubate at 37°C for 60 minutes. (Recommendation: Dilute the sample to be tested at least 1-fold with universal diluent before adding it to the ELISA plate. This will reduce the impact of matrix effects on the test results. The sample concentration should be multiplied by the corresponding dilution factor when calculating the final sample concentration. It is recommended to run replicates for all test samples and standards.) 3. Add Biotinylated Antibody: Remove the ELISA plate and discard the liquid without washing. Add 100 μL of Biotinylated Antibody Working Solution directly to each well. Cover with a film and incubate at 37°C for 60 minutes. 4. Wash: Discard the liquid and add 300 μL of 1x Wash Solution to each well. Let stand for 1 minute, shake off the wash solution, and pat dry on absorbent paper. Repeat this process three times (a plate washer can also be used). 5. Add Enzyme Conjugate Working Solution: Add 100 μL of Enzyme Conjugate Working Solution to each well. Cover with a film and incubate at 37°C for 30 minutes. 6. Washing: Discard the liquid and wash the plate five times as in step 4. 7. Adding substrate: Add 90 μL of substrate (TMB) to each well, cover with a sealing film, and incubate at 37°C in the dark for 15 minutes. 8. Adding stop solution: Remove the ELISA plate and add 50 μL of stop solution directly to each well. Immediately measure the OD value of each well at a wavelength of 450 nm. Calculating experimental results: 1. Calculate the average OD value of the standard and sample replicates and subtract the OD value of the blank well as a correction factor. Plot the standard curve of the four-parameter logistic function on double-logarithmic graph paper, with concentration as the horizontal axis and OD value as the vertical axis. 2. If the sample OD value is higher than the upper limit of the standard curve, dilute the sample appropriately and retest. Multiply the sample concentration by the corresponding dilution factor. |
|||||||||||||||||||||||||||||||||
| Theory | This kit uses a double-antibody sandwich enzyme-linked immunosorbent assay (ELISA). Sample, standard, biotin-labeled detection antibody, and HRP conjugate are sequentially added to microwells pre-coated with a capture antibody against lipase and monoacylglycerol (MGL). After incubation and washing, the sample is developed using the substrate TMB. TMB converts to blue under the catalysis of HRP and to yellow under the action of acid. The intensity of the color is positively correlated with the amount of lipase and monoacylglycerol (MGL) in the sample. The absorbance (OD) is measured at 450 nm using a microplate reader to calculate the sample concentration. | |||||||||||||||||||||||||||||||||
| Source | Human | |||||||||||||||||||||||||||||||||
| Synonym | Human Lipase, Monoacylglycerol ELISA Kit | |||||||||||||||||||||||||||||||||
| Detection Type | Double antibody sandwich method | |||||||||||||||||||||||||||||||||
| Composition |
|
|||||||||||||||||||||||||||||||||
| Background | Monoacylglycerol lipase (MGL), also known as MAG lipase, acylglycerol lipase, MAGL, MGL, or MGLL, is an enzyme encoded by the MGLL gene. It is a 33 kDa, membrane-associated member of the serine hydrolase superfamily and contains the classic GXSXG consensus sequence common to most serine hydrolases. The catalytic triad has been identified as Ser122, His269, and Asp239. It catalyzes a chemical reaction that utilizes water molecules to break down monoglycerides of long-chain fatty acids. It works alongside hormone-sensitive lipase (LIPE) to hydrolyze triglyceride stores within adipocytes and other cells into fatty acids and glycerol. It also complements lipoprotein lipase (LPL) to complete the hydrolysis of monoglycerides produced by the degradation of lipoprotein triglycerides. | |||||||||||||||||||||||||||||||||
| General Notes | 1. Strictly adhere to the specified incubation time and temperature to ensure accurate results. All reagents must be at room temperature (20-25°C) before use. Refrigerate reagents immediately after use. 2. Improper plate washing may result in inaccurate results. Ensure that all liquid in the wells is aspirated thoroughly before adding substrate. Do not allow the wells to dry out during incubation. 3. Remove any residual liquid and fingerprints from the bottom of the plate, as this will affect the OD value. 4. The substrate developer solution should be colorless or very light in color. Do not use substrate solution that has turned blue. 5. Avoid cross-contamination of reagents and specimens to prevent erroneous results. 6. Avoid direct exposure to strong light during storage and incubation. 7. Do not expose any reagents to bleaching solvents or the strong fumes emitted by bleaching solvents. Any bleaching agent will destroy the biological activity of the reagents in the kit. 8. Do not use expired products, and do not mix components with different product numbers and batches. 9. Recombinant proteins from sources other than the kit may not be compatible with the antibodies in this kit and will not be recognized. 10. If there is a possibility of disease transmission, all samples should be managed properly and samples and testing devices should be handled according to prescribed procedures. |
|||||||||||||||||||||||||||||||||
| Storage Temp. | If the unopened kit is stored at 4°C, the shelf life is 6 months. | |||||||||||||||||||||||||||||||||
| Test Range | 0.156-10 ng/mL | |||||||||||||||||||||||||||||||||
| Applications | Tissue homogenates and other biological fluids |
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy
4.3 ★★★★★
Based on 21 reviews
Sort
Product Reviews
★★★★★ 5
Great quality and easy to assemble!
Color: Blues, Size: 56 LB, Color: Blues, Size: 56 LB
I’m really happy with this dumbbell set. The stand was very easy to assemble and feels sturdy once put together. The neoprene coating on the weights is comfortable to grip and doesn’t slip, even when your hands get a little sweaty. I also love the colors—they make the set look nice in my workout space. Perfect for home workouts, compact, and easy to move around. Definitely worth it if you’re looking for a practical and stylish weight set!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on October 3, 2025
★★★★★ 5
Like new after years of use. Made to last.
Color: Multicolor, Size: 146 LB
Sturdy, well made, good feel. I purchased the set 2 years ago and it's still like new!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 2, 2026
★★★★★ 5
Nice weight set for taking strength off to a new start.
Color: Multicolor, Size: 12 LB
Perfect light weight set to use to rebuild my arm strength. Holder is a bonus. Now the weights will be right where I want them
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on June 1, 2026
★★★★★ 5
Happy customer
Color: Black, Size: 32 LB, Color: Black, Size: 32 LB
I recently purchased a set of black dumbbell weights, and I couldn't be happier with my decision!
These dumbbells are solid and built to last. The weight material feels durable, and I can tell they're gonna last. These weights are perfect for all my exercises. They come in a range of sizes, allowing me to easily adjust the weight for different muscle groups. I love the sleek black finish! It not only looks stylish in my home gym but also adds a touch of professionalism to my space. The price point is excellent considering the quality and durability of these dumbbells. I've seen similar products at a much higher price, but these offer the same benefits without breaking the bank. Their design makes them easy to grip, and the smooth texture ensures I can maintain my hold even during the sweatiest workouts. Plus, they're compact and easy to store, making them perfect for home use.
Overall, these dumbbell weights check all the boxes. I highly recommend them to anyone looking to enhance their fitness journey!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on September 9, 2024
★★★★★ 4
Great Set
Color: Multicolor, Size: 146 LB
This is a great set of dumbbells. I was looking for the weights in this set and I wanted a nice rack to keep them off the floor. So far they feel solid and accurate and are working as expected. The reason for 4 stars and not 5 - The (2) 20 pound dumbbells shipped separate, which was fine...but everything else was in 1 box! That's 106 pounds plus the rack and packaging. The delivery guy struggled and almost dropped it, and then I had to move it from my front door step. How much more could it cost them to ship it in 3 boxes or redistribute it into 2 boxes under 100 pounds? So lucky the box didn't drop and the contents get lost or wrecked.
Otherwise it is a great set!
WAS THIS REVIEW HELPFUL?YesReportShare
Reviewed in the United States on January 18, 2025
recommand products
07-12 Lexus XF40 LS460 Front Right Passenger Side Fender Upper Molding Trim OEM
41.50
07-09 Jaguar XKR XK X150 Front Right Passenger Side Door Control Module Unit OEM
32.00
10-23 Jaguar X351 XJ F-Type Front Left Driver Brake Caliper Assembly OEM
59.95
Elegant Portrait of Samuel Rea: Iconic Railway Executive in Contemporary Art – A Captivating Gift for Home Decor Enthusiasts
24.00
PROJECTIONDESIGN TDP-F1 Compatible Module with Original Bulb, Applicabler Projectors: F1 SXGA , Alt. LampPart Number: 400-0003-00 | 03-000710-01P | 001-821
344.92