Pay in installments of $50.29 with
,
and
Shipping Estimate
USA
- USA
- CAN
- USA
- CAN
Ships within 48 hours · Estimated delivery Jul 25 - Jul 30
For Your Every Summer RSVP, with Code: SUMMER15
Description
Eaton Tripp Lite Series 2.9kW 120V Single-Phase Basic PDU - 24 NEMA 5-15/20R Outlets, L5-30P Input, 10 ft. Cord, 63.75 in. 0U RackThe Eaton Tripp Lite Series 2. 9kW 120V Single Phase Basic PDU is a reliable power distribution solution designed to meet the demanding needs of small to mid size data centers, computer rooms, and network closets. This compact, robust PDU ensures critical equipment receives stable power with the versatility to support a dense rack environment. Built to simplify electrical management, it delivers efficient distribution to multiple devices while fitting
The Eaton Tripp Lite Series 2.9kW 120V Single-Phase Basic PDU is a reliable power distribution solution designed to meet the demanding needs of small to mid-size data centers, computer rooms, and network closets. This compact, robust PDU ensures critical equipment receives stable power with the versatility to support a dense rack environment. Built to simplify electrical management, it delivers efficient distribution to multiple devices while fitting neatly into a standard 19-inch rack configuration. Ideal for IT cabinets that require a cost-effective, essential PDU, this model helps you maximize uptime and keep networked systems running smoothly.
- Power capacity and configuration: 2.9 kW at 120V, single-phase operation, providing dependable distribution for racks with diverse equipment while maintaining performance consistency across outlets.
- Outlet count and type: 24 NEMA 5-15R/5-20R receptacles allow flexible connections for a wide range of servers, switches, and peripherals without needing additional adapters or power strips.
- Input and cord: L5-30P locking input connector paired with a 10-foot cord offers secure, versatile power sourcing with ample length to reach standard power outlets in most data centers or equipment rooms.
- Rack compatibility and footprint: Designed for 0U installation with a substantial 63.75-inch depth, enabling full utilization of rack space while keeping cables organized and accessible for maintenance.
- Target applications: Specifically suited for small to mid-size data centers, server rooms, and network closets where a straightforward, dependable PDU is essential for centralized power distribution and equipment reliability.
Technical Details of Eaton Tripp Lite Series 2.9kW 120V Single-Phase Basic PDU
- Power rating: 2.9 kW (120V, single-phase)
- Output receptacles: 24 x NEMA 5-15R/5-20R outlets
- Input connector: L5-30P locking inlet
- Cord length: 10 feet
- Chassis/rack compatibility: 0U rack-mountable with a depth of 63.75 inches
- Voltage and phase: 120V, single-phase
How to install Eaton Tripp Lite Series 2.9kW 120V Single-Phase Basic PDU
- Plan your rack layout and identify a suitable location for the PDU within the cabinet to minimize cable clutter and ensure easy access to outlets.
- Mount the PDU to the 19-inch rack using compatible hardware, ensuring it is securely installed in a 0U position to maximize available space for equipment.
- Connect the 10-foot cord to a properly rated 120V power source, using the L5-30P locking inlet to ensure a secure connection and reduce the risk of accidental unplugging.
- Route and organize cables from servers, switches, and other devices to the 24 NEMA 5-15R/5-20R outlets, labeling outlets if needed to simplify future maintenance and hot-swapping of components.
- Power on the rack and verify that all connected devices receive stable power and that there are no loose connections or cable interference with cooling airflow.
Frequently asked questions
-
Q: What is the power capacity of this PDU?
A: It delivers up to 2.9 kW at 120V in a single-phase configuration, suitable for moderate rack loads. -
Q: How many outlets does the PDU provide?
A: It features 24 NEMA 5-15R/5-20R outlets to accommodate multiple devices without needing extra power strips. -
Q: What type of input plug is used?
A: The PDU uses a locking L5-30P input connector with a 10-foot cord for secure, flexible power delivery. -
Q: Is this a 0U rack-mount PDU?
A: Yes, it is designed for 0U installation, with a deep chassis (63.75 inches) to fit within standard 19-inch racks. -
Q: What environments is this PDU best suited for?
A: It is ideal for small to mid-size data centers, computer rooms, and network closets needing reliable, centralized power distribution.
Shipping Notes
- Free Standard Shipping on $100+ Orders to the USA.
- Except Preorder products are shipped in 48 hours.
- Delivery to the USA:
- Standard Shipping : 3-10 business days
- If time is of the essence, please consider selecting expedited delivery for faster service.
Exchange/Return Notes
- We offer a 30-day return/exchange service after receiving.
- Final sale items are not eligible for returns or exchanges.
- To process your return/exchange, please contact us at [email protected]
- Please click here for more details>>> Return & Exchange Policy